New 720 Watt Inverter / Charger - Mecer - 12 Volt View larger

720 Watt Inverter / Charger - Mecer - 12 Volt

INVERTER720

New product

R 2,100.00 tax incl.

Add to wishlist

Credit Card or EFT
Credit Card or EFT

More info

 720W 12V Inverter - Modified Sine wave

It has an auto switchover feature and a built in charger.

Meaning your equipment can run off the mains (220 volts) and when loadshedding happens it will switch over to the battery automatically.

Your equipment will not see the difference. Your PC will still be running and your decoder will not loose signal.

 

All you need to add is a battery. Once the loadshedding is over,  the unit will charge the battery for the next round of loadshedding.

We've tested this particular inverter by running a PC with a 23" screen, an inkjet printer, a small p1102 laser printer and a DSTV decoder.

We printed several pages on the laser printer just to see if it could take the load and it did. ( Our printer takes 360 Watts when printing, but most laser printer take between 400 to 750 watts.)

 

Below you'll find all the technical specs:

 

Features

• Simulated sine wave inverter

• Built-in AVR for voltage regulation

• Wide input voltage range: 90-280 VAC

• 12VDC available

• Overload and short circuit protection

• LCD display for comprehensive information

Specifications

 MODEL  Mecer IVR-1200LBK
CAPACITY  1200 VA / 720 W
POWER FACTOR 0.8
Input Voltage range 90-280VAC
LINE MODE  
Output Voltage

Bypass mode: 0utput voltage same as input voltage

AVR mode:Output voltage = Input voltage*1.2 @ Input voltage<200VAC

Output Frequency Same as input
BATTERY MODE  
Output Voltage  230Vac ±10%
Transfer Time  20ms typical
Waveform   Modified Sine-wave
OVERLOAD CAPABILITY  
Bypass Mode (in VA and Watts)  Load >110%±15% , alarm 5 mins then fault
 Load >130% ±15%, fault immediately.
AVR Mode (in VA and Watts)@ Input voltage > 170VAC  Load >100%±15%, go to bypass mode
AVR Mode (in VA and Watts)@ Input voltage < 170VAC Load >60%±15%, go to bypass mode
Battery Mode (in W)  Load>110% ±15%, overload alarm for 15s, and then will switch to fault mode for 10s. Then unit will re-start for 5 times
Load>120% ±15% , fault & cut off O/P immediately. 
SHORT CIRCUIT PROTECTION  
Line Mode Breaker
Battery Mode Current limit +Firmware Protection
BATTERY  
Battery Voltage  12VDC
Acceptable Battery Type Rechargeable lead-acid battery, Deep discharge battery
Polarity Reserve Protection Yes
Charger available I/P range 90~280V
CHARGER  
Constant Current Charger Voltage 14.3VDC ±2%
Floating Charge Voltage 13.7VDC ±2%
Maximum Charge Current 10A or 20A
DC Start Voltage >11VDC
PHYSICAL  
 Dimension, D X W X H (mm)  350 x 90 x 300
 Net Weight (kgs)  4.5
ENVIRONMENT  
Operating Humidity  0 to 90% Relative Humidity(Non-condensing)
Operating Temperature 0? to 40?
Storage Temperature -15? to 50?